Wiring |10kW and 25kW Installation Manual
Wiring
Guidelines
When wiring the radar:
DON’T make sharp bends in the cables
DON’T run cables in a way that allows water to  ow down on to the connectors
DON’T allow the scanner cable to place pressure on the radar processor connector
But:
DO make drip and service loops
DO use cable ties to keep the cables tidy and secure
DO seal and protect all wiring connections if cables are shortened, lengthened, or re-
terminated
DO leave room to easily access, install and remove cables
DO make sure cables connecting to the radar processor are not under stress from bending or
twisting that could place pressure on the processors connectors
Radar scanner: 10 kW
Fitting the scanner cable
1. Unscrew the four cover bolts and lift up the hinged cover of the pedestal.
2. Remove the cable gland assembly from the lower half of the pedestal cover.
3. Pass the scanner end of the scanner cable through the cable gland (1), plain washer (2), rubber
gasket (3) and another plain washer (4), in the order shown.
4. Unravel the braided shield and wrap it around the washer (4).
4