SimradMS70
Environmentalrequirements
Thissectionprovidesthetechnicalspecicationsandrequirementsrelatedtothe
environmentalconditions.
DisplayUnit
Notapplicable.Refertothedocumentationprovidedbythemanufacturer.
MultibeamOperatorStation
Operationaltemperature:0+50°C
Storagetemperature:–40+70°C
Maximumambientrelativehumidity,nocondensation,operation:885%
Maximumambientrelativehumidity,nocondensation,storage:895%
TransceiverUnit
Operationaltemperature:10+30°Cwithamaximumtemperaturegradationof
10°Cperhour
Storagetemperature:–40+65°C
Maximumambientrelativehumidity,nocondensation,operation:2080%with
maximumhumiditygradationof10%perhour
Maximumambientrelativehumidity,nocondensation,storage:895%
PowerSupplyUnit
Operationaltemperature:0+30°C
Storagetemperature:–40+65°C
Maximumambientrelativehumidity,nocondensation,operation:885%
Maximumambientrelativehumidity,nocondensation,storage:895%