Simrad TRANSDUCER - INSTALLATION GENERIC REV H Manuel d'installation Page 28

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 212
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 27
SimradMS70
Insulation
Bulkheadsmustbeinsulatedandprovidedwithaninteriorwalltothedeck.The
insulationshouldbetheminimumequivalentof50mmofrock-wool.Inaddition,piping
passingthroughthespacepronetocondensationmustbeinsulated.
Ventilation
Thesonarroommustbeconnectedtothevessel’sventilationsystem.Ifthisisnot
possible,two3”ventsmustbeprovidedfromthesonarroomtothemaindeck.Inthe
room,theairinletmustwheneverpossiblebelocatedclosetothedeckandtheoutletas
highaspossible.Afunnelshapeddrip-collectormustbemountedbelowtheventpipes
todivertmoisturetothebilge.Onthemaindeck,thebestventilationisprovidedwhen
theoutletpipeisatleastfourmetershigherthantheinletpipe.Tokeepoutseawater,
rainandspray,theventilationpipesshouldbettedwithgoosenecksortheequivalent.If
thevesselislikelytooperateintropicalconditions,asuitableairconditioningsystem
mustbeinstalled.Thissystemmustbeabletoprovideanambienttemperaturenot
exceedingthemaximumoperatingtemperaturesforthecabinetsinstalledintheroom.
Cableprotection
Ifthecablesbetweenthesonarroomequipmentandothersystemunitslocatedin
differentcompartmentsonthevesselpassthroughhatchesorareaswheretheymaybe
damaged,theymustberunthroughconduits(minimum2”conduitisrecommended).
Electricalinstallationsandlights
Thesonarroommustbeequippedwithsuitablelightingtosimplifytheinstallationand
toaidfuturemaintenance.Aminimumnumberofelectricaloutletsmustbeprovided
forthesystemunitsandotherequipment.
Bilgepumpanddecking
Ifthesonarroomislocatedbelowthewaterline,itmustbeconnectedtothevessel’s
bilgepumpsystem.Ifthisisnotpossible,aseparatebilgepumpforthesonarroommust
beinstalled.Oncetheinstallationhasbeencompleted,thesonarroommustbesuitably
deckedwithoutrestrictingaccesstotheequipmentandthecables.
Cablingrequirements
AdetailedcableplanisprovidedfortheinstallationoftheSimradMS70.
Cableplansonpage82
Thecablesfallintothefollowingcategories:
InternalcableswithintheTransceiverUnitrack
EthernetcablesbetweentheTransceiverUnitrackandtheOperatorStation,and
betweentheMS70systemandexternalnetwork(s).
Interfacecablestoexternalsensors
26
331549/B
Vue de la page 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 211 212

Commentaires sur ces manuels

Pas de commentaire