TransceiverUnitassembly
Procedure
1Removethetwoearthstrapsontherighthandsideofthetransceivercabinet.
2Removealltheremaining20boltsthataretemporarilymountedintotheirfront
holes.
3Oneachofthesixrails(threeoneachside),dismountthesiderailthatshallbe
mountedontotheTRXUracks.
Figure26Removethesiderail(A)byunlockingit(B)
4RemovetherailboltsfromthetwosidepanelsoneachTRXUrack.
5Usethesameboltstomountthetwosiderails.
Figure27Mounteachsiderailswiththreebolts(A)
Note
Donotuseexcessive
forcewhenyoutighten
theboltsforthesiderails.
M
a x i m u m t o r q u e i s 1 3 0
N c m . Theseboltsare
insertedintonutsonthe
insideofthesubracks,and
ifyoutightentoohard,you
maydamagethethreads.
6Pushtherailsmountedon
thesideofeachrackintotherailsonthecabinet,andpushtherackc
a r e f u l l y in.
Youmaynditusefultoloosentheboltsonthefandrawersoverand/orunderthe
TRXUrack.
Note
MakesurethatyoudonotdamageanyoftheEthernetcables!
7Securethesubrackwiththefrontbolts,fouroneachside.
8Mountthetwoearthstraps.
Notethattheboltsusedtomounttheearthstrapsareslightlylongerthantheothers.
331549/B
71